Black Box Universal RS‑232 to RS‑422/RS‑485 Opto‑Isolated Converter, DB9 to Terminal Block (IC821A)
$152.99
The BLACK BOX Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector
| Brand | Black Box |
|---|
The BLACK BOX Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wall mount Power Supply (PS1003). For RS-232, the connection requires RD, TD, and Signal Ground. In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required to receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire. In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use. To connect to several RS-485 devices with minimal wire, select the unit’s 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire. For 4-wire master/slave circuits, select the unit’s 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
Operates 2-wire half-duplex or 4-wire half- or full-duplex. async (data leads) only. Up to 32 RS485 devices can be attached to create a large multi-drop network Operates in point to point or multipoint applications Transmit data up to 115 kbps or at distances up to 4000 ft.
- Operates 2-wire half-duplex or 4-wire half- or full-duplex.
- async (data leads) only.
- Up to 32 RS485 devices can be attached to create a large multi-drop network
- Operates in point to point or multipoint applications
- Transmit data up to 115 kbps or at distances up to 4000 ft.
Our goal is to ensure a seamless and transparent shipping process for your convenience and satisfaction. Below are the details of our shipping process.
Our goal is to ensure a seamless and transparent shipping process for your convenience and satisfaction. Below are the details of our shipping process:
Shipping Range
- Countries: We currently ship to Canada and the United States.
- Future Expansion: We are considering expanding to other regions in the future.
Shipping Costs
- Within Canada: Free shipping on all orders.
- Within the United States: Free shipping on all orders.
- No Hidden Fees: All costs are clearly stated at checkout.
ORDER PROCESSING TIME
- Processing Time: Orders are processed within 1-2 business days, Monday to Friday- (GMT-07) Mountain Standard Time (Edmonton)
- Last Order Time: 22:00 (GMT-07) Mountain Standard Time (Edmonton)
- Weekend Orders: Orders placed on weekends are processed the next business day.
TRANSIT TIME
- Estimated Delivery Time: 1-2 business days.
- Business Days: Shipments occur Monday to Friday.
- Notes: Delivery times are estimates and may vary due to external factors such as weather conditions and transportation issues.
SHIPPING PROCESS
- Reliable Courier Services: We ship via DHL and Fedex and UPS
- Insured Shipments: All shipments are insured. Contact our customer service in case of loss or damage during transit.
- Eco-Friendly Packaging: We strive to use sustainable packaging materials to minimize our ecological footprint.
TRACKING INSTRUCTIONS
- Tracking Information: After purchase, you will receive an email with tracking information, including the name of the shipping company and the tracking number.
- Track Your Order: You can track your order via our website. Simply enter your tracking number on our tracking portal to view the status of your order.
- Questions: Our support team is ready to assist with any questions about tracking your order.
MISSING ITEMS PROCEDURE
- Reporting Missing Items: Contact our customer service within 7 days of receiving your package via support@simolary.com
- Resolution: We will resolve the issue as soon as possible and send a replacement item or offer a refund.
RETURN POLICY
- Returns: Returns are accepted within 30 days of receiving your order.
- Conditions for Returns: Items must be unused, undamaged, and returned in the original packaging. Personalized items cannot be returned.
- Costs: Return shipping costs are the responsibility of the customer unless the item is defective or not as described. In such cases, Simolary LLC
will cover the return shipping costs. - Refund: Refunds are processed within 14 days of receiving the return and are refunded to the original payment method.
-Address return :
SIMOLARY LLC WAREHOUSE
168 Prestwick Manor SE, Calgary, AB T2Z 4Y7, Canada - Questions?
Visit our FAQ page or contact our customer service via email : support@simolary.com
Reviews
There are no reviews yet.